    David J. Ruskey (Davegn) | Saturday, April 20, 2002 - 01:27 pm  I have an 87 GN and the coolant fan will not come on at all.The stock setup won't energize and neither will my manual switches work. the only way I get it to work is to hook my switch directly to the fan.I've checked all the fuses o.k. I have replaced all 3 relays and the coolant fan temp. sensor and still nothing. I know I'm getting a ground all the way to the fan , but no 12volts. I've been trouble shooting for days and I don't know what else to check. NEED HELP FAST |
    David J. Ruskey (Davegn) | Sunday, April 21, 2002 - 04:20 pm  I found that i'm not getting 12v on any of the 10awg (red) wires going to the fan relays . could it be the fusible link? if so where is the fusible link ? any other ideas |
    Dale Hutchinson (Dalehutch) | Sunday, April 21, 2002 - 08:47 pm  Might be.... I had the same problem after I replaced my starter. I learned that I didn't put one red fusible link on the starter terminal. |
    Dale Schonauer (Dale) | Monday, April 22, 2002 - 08:18 am  After the fan relay failed twice I decided to replace the factory system with a "painless" wiring system from Summit. Includes relay and a sensor that turns on the fan at 180 and off at 175. Works perfect. |
    David J. Ruskey (Davegn) | Sunday, April 28, 2002 - 07:42 am  Thanks Dale, you pointed me in the right direction . The problem was the fusible link at the starter. I'm so glad to have this fixed, thanks again. |